Journal of Arak University of Medical Sciences
مجله دانشگاه علوم پزشكي اراك
J Arak Uni Med Sci
Medical Sciences
http://jams.arakmu.ac.ir
46
journal46
1735-5338
2008-644X
fa
jalali
1396
10
1
gregorian
2018
1
1
20
10
online
1
fulltext
fa
مقایسه یافتههای تیمپانومتری فرکانس بالا و فرکانس پایین در نوزادان هنجار
Comparison of High Frequency and Low Frequency Tympanometry Findings in Normal Neonates
علوم پایه
Basic Sciences
پژوهشي اصیل
Original Atricle
<div style="text-align: justify;"><strong><span style="font-family:b mitra;"><span style="font-size:12.0pt;">چکیده</span></span></strong><br>
<strong><span style="font-family:b mitra;"><span style="font-size:12.0pt;">زﻣﯿﻨﻪ و ﻫﺪف:</span></span></strong> <span style="font-family:b mitra;"><span style="font-size:12.0pt;">تیمپانومتری به عنوان یکی از مهم­ترین ارزیابی های ادیولوژیکال در برنامه های غربال­گری شنوایی نوزادان مطرح می باشد. این آزمون به صورت معمول با استفاده از پروب فرکانس 226 هرتز انجام می شود؛ با این حال در نوزادان کمتر از 6 ماه، استفاده از این پروب فرکانس به دلیل خصوصیات متفاوت گوش میانی نسبت به بزرگسالان قابل اعتماد نیست. هدف از مطالعه حاضر، ارزیابی اطلاعات به دست آمده از تیمپانومتری در نوزادان دارای شنوایی هنجار 1 تا 14 روزه، با استفاده از پروب فرکانس های 226، 678، 800 و 1000 هرتز می باشد.</span></span><br>
<strong><span style="font-family:b mitra;"><span style="font-size:12.0pt;">مواد و روش ها:</span></span></strong><span style="font-family:b mitra;"><span style="font-size:12.0pt;"> در این مطالعه مقطعی، 30 نوزاد 1 تا 14 روزه که با استفاده از آزمون گسیل های صوتی گوش از لحاظ شنوایی هنجار شناخته شده بودند، تحت ارزیابی تیمپانومتری قرار گرفتند. آزمون تیمپانومتری با استفاده از پروب فرکانس های 226، 678، 800 و 1000 هرتز برای هر دو گوش انجام شد. برای تحلیل داده ها از روش آماری تی زوجی استفاده شده است.</span></span><br>
<strong><span style="font-family:b mitra;"><span style="font-size:12.0pt;">یافته ها</span></span></strong><span style="font-family:b mitra;"><span style="font-size:12.0pt;">: با استفاده از پروب فرکانس 226 هرتز، موارد بروز تیمپانوگرام دوقله ای غیرمعمول در</span></span> <span style="font-family:b mitra;"><span style="font-size:12.0pt;">65 درصد موارد دیده شد که با افزایش فرکانس پروب تن، این درصد کاهش یافت. هم­چنین، میزان استاتیک ادمیتانس جبران شده در دو فرکانس 226 و 1000 هرتز، اختلاف معناداری داشت.</span></span><br>
<strong><span style="font-family:b mitra;"><span style="font-size:12.0pt;">نتیجه گیری:</span></span></strong><span style="font-family:b mitra;"><span style="font-size:12.0pt;"> در نوزادان تازه متولد شده هنجار و بدون عوامل خطر برای کم شنوایی، تیمپانوگرام 1000 هرتز وضعیت گوش میانی را نسبت به تیمپانوگرام 226 هرتز بهتر نشان می دهد.</span></span><br>
</div>
<div style="text-align: justify;"><span style="font-size:14px;"><span style="font-family: times new roman;"><strong>Abstract</strong><br>
<strong><em>Background:</em></strong> Tympanometry is one of the most important audiological tests for the assessment of neonatal hearing screening programs. This test is usually done using a 226 Hertz probe tone; however, in infants less than 6 months of age, using this probe tone frequency is not reliable due to the different characteristics of the middle ear compared to adults. The purpose of this study was to assess the obtained tympanometric data in neonates 1 to 14 days with normal hearing using 226, 678, 800 and 1000 Hertz frequency probes tones.<br>
<strong><em>Materials and Methods:</em></strong> In this cross-sectional study, 30 neonates aged 1 to 14 days who were diagnosed as normal in hearing aspect with using otoacoustic emissions test, were assessed by tympanometry. Tympanometric tests were performed using 226, 678, 800 and 1000 Hertz frequency probe tones for both ears. For data analysis, the T-paired method has been used.<br>
<strong><em>Results:</em></strong> With using 226 Hertz frequency probe tone, incidence of unusual double peak tympanograms was observed in 65% of cases, which with increasing frequency of the probe tone, this percentage was decreased. There was also a statistically significant difference between the static admittance peak compensated in two 226 and 1000 Hertz frequency probes tones.<br>
<strong><em>Conclusion:</em></strong> In neonates with normal hearing and without any risk factors for hearing loss, the 1000-Hertz Tympanogram shows a better middle ear status than the 226-Hertz tympanogram.</span></span><br>
</div>
فرکانس بالا, فرکانس پایین, نوزاد, تیمپانومتری
High frequency, Low frequency, Neonate, Tympanometry
20
28
http://jams.arakmu.ac.ir/browse.php?a_code=A-10-4046-1&slc_lang=fa&sid=1
Mahdi
Panahian
مهدی
پناهیان
aud.mahdi@yahoo.com
4600319475328460058664
4600319475328460058664
Yes
Department of Audiology, Faculty of Rehabilitation Sciences, Arak University of Medical Sciences, Arak, Iran
گروه شنواییشناسی، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی اراک، اراک، ایران
Ehsan
Nafari
احسان
نفری
4600319475328460058665
4600319475328460058665
No
Faculty of Rehabilitation Sciences, Ahvaz University of Medical Sciences, Ahvaz, Iran
دانشکده علوم توانبخشی، دانشگاه علوم پزشکی اهواز، اهواز، ایران
Nasim
Daneshdoost
نسیم
دانشدوست
4600319475328460058666
4600319475328460058666
No
Faculty of Rehabilitation Sciences, Ahvaz University of Medical Sciences, Ahvaz, Iran
دانشکده علوم توانبخشی، دانشگاه علوم پزشکی اهواز، اهواز، ایران
Danial
Habibi
دانیال
حبیبی
4600319475328460058667
4600319475328460058667
No
Department of Biostatistics, Faculty of Medicine, Arak University of Medical Sciences, Arak, Iran
گروه آمار زیستی، دانشکده پزشکی، دانشگاه علوم پزشکی اراک، اراک، ایران