<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Arak University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشكي اراك</title_fa>
<short_title>J Arak Uni Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jams.arakmu.ac.ir</web_url>
<journal_hbi_system_id>46</journal_hbi_system_id>
<journal_hbi_system_user>journal46</journal_hbi_system_user>
<journal_id_issn>1735-5338</journal_id_issn>
<journal_id_issn_online>2008-644X</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61882/jams</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1398</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2020</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>22</volume>
<number>6</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تأثیر عناصر تشکیل‌دهنده فانتوم بر محاسبات دز در پروتون‌تراپی سرطان کبد</title_fa>
	<title>The Effect of Phantom Compositions on Dose Calculations in Proton Therapy of Liver Cancer</title>
	<subject_fa>علوم پایه</subject_fa>
	<subject>Basic Sciences</subject>
	<content_type_fa>پژوهشي اصیل</content_type_fa>
	<content_type>Original Atricle</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot; style=&quot;margin: 0px; unicode-bidi: embed; direction: rtl; text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:tahoma;&quot;&gt;&lt;font color=&quot;#000000&quot;&gt;&lt;span b=&quot;&quot; lang=&quot;AR-SA&quot; style=&quot;margin: 0px; font-family: &quot;&gt;&lt;strong&gt;زمینه و هدف&lt;/strong&gt;: از آنجا که در بسیاری از کارهای شبیه&#8204;سازی، از یک فانتوم ساده آب و همچنین گهگاه از فانتوم بافت نرم در محاسبات دزیمتری استفاده می&#8204;شود، این مطالعه به بررسی تفاوت&#8204;های بین دو فانتوم ذکرشده با فانتوم متشکل از مواد و عناصر واقعی کبد، در پروتون&#8204;تراپی سرطان کبد پرداخته است.&amp;nbsp;&lt;br&gt;
&lt;strong&gt;مواد و روش ها&lt;/strong&gt;: سه فانتوم با عناصر متفاوت برای کبد، شامل آب، بافت نرم و فانتوم شامل عناصر اصلی کبد در نظر گرفته شد. توموری کروی&#8204;شکل به شعاع دو سانتی&#8204;متر در کبد در نظر گرفته شده و قله براگ پهن&#8204;شده جهت پوشاندن کل تومور برای سه فانتوم ذکرشده محاسبه شد. شیوه توزیع دز و نسبت دز تخلیه&#8204;شده در تومور و اندام&#8204;های اطراف آن با استفاده از کد مونت کارلوی MCNPX محاسبه شد.&lt;br&gt;
&lt;strong&gt;ملاحظات اخلاقی:&lt;/strong&gt; در این مورد قبلا مکاتبات انجام شده است. با توجه به شبیه سازی بودن مطالعه، نیازی به کد اخلاق وجود نداشت.&lt;br&gt;
&lt;strong&gt;یافته ها&lt;/strong&gt;: نتایج نشان دادند برای بافت نرم و بافت اصلی کبد، قله&#8204;های براگ در بازه انرژی MeV ۱۲۰ MeV - ۹۰ و برای فانتوم آب بازه MeV ۱۱۶ MeV - ۸۸ محدوده تومور را می&#8204;پوشاند. تفاوت مکان تخلیه دز برای فانتوم آب در هر انرژی نسبت به دو فانتوم دیگر به صورت تقریبی ۵/۴ میلی&#8204;متر در هر نقطه است. پارامترهای ارزیابی دز طبق گزارش کمیسیون بین&#8204;المللی واحدهای تابش (ICRU) به دست آمدند که تفاوت چندانی بین نتایج دیده نشد. توزیع دز در تومور و اندام&#8204;های اطراف آن نشان می&#8204;دهند برای هر سه فانتوم، توزیع دز اطراف تومور بسیار ناچیز است.&lt;br&gt;
&lt;strong&gt;نتیجه گیری:&lt;/strong&gt; نتایج نشان می&#8204;دهند استفاده از فانتوم بافت نرم نتایج قابل قبول&#8204;تری برای شبیه&#8204;سازی درمان نسبت به فانتوم آب برای جایگزینی بافت واقعی کبد دارد و در طراحی درمان باید بیشترین تلاش برای استفاده از فانتوم&#8204;های واقعی&#8204;تر باشد.&lt;/span&gt;&lt;/font&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot; style='margin: 0px; font-family: &quot;B Nazanin&quot;;'&gt;&lt;/span&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p style=&quot;margin: 0px 0px 13.33px; text-align: justify;&quot;&gt;&lt;font color=&quot;#000000&quot;&gt;&lt;span style=&quot;margin: 0px; line-height: 115%; font-family: &quot;&gt;&lt;strong&gt;Background and Aim:&lt;/strong&gt; Sicne in many dosimetry calculations, the water and soft tissue phantoms are used, this study aimed to investigate the difference of these two phantoms with a phantom consisted of realistic liver materials in proton therapy for liver cancer.&lt;br&gt;
&lt;strong&gt;Methods &amp; Materials&lt;/strong&gt;: Three phantoms with different materials of water, soft tissue and realistic liver materials were used for the study. A spherical tumor with 2 cm radius was considered in the liver. The Spread-out Bragg Peaks (SOBPs) were measured to cover the complete tumor for the three phantoms. Dose distribution and deposited dose ratio in tumor and surrounding organs were calculated using Monte Carlo N-Particle Extended (MCNPX) code.&amp;nbsp;&lt;br&gt;
&lt;strong&gt;Ethical Considerations&lt;/strong&gt;: The best proton energy interval to complete the coverage of tumor in the liver for phantoms with realistic and soft tissue materials was 90-120 MeV and for water phantom, it was 88-116 MeV. The shift of the Bragg peaks depth per energy in the water phantom mm relative to two other phantoms was about 4.5. The dose parameters were evaluated according to the International Commission on Radiation Units and Measurements (ICRU), and the results showed no any significant difference between them. The dose distribution in the tumor and surrounding organs showed that for all three phantoms, the dose distribution around the tumor was negligible.&lt;br&gt;
&lt;strong&gt;Results&lt;/strong&gt;: The use of soft tissue phantom has more acceptable results than water phantom in simulating treatment and can be replaced with realistic liver tissue. More realistic phantoms should be used in treatment plan.&amp;nbsp;&lt;br&gt;
&lt;strong&gt;Conclusion&lt;/strong&gt;: The use of soft tissue phantom has more acceptable results than water phantom in simulating treatment and can be replaced with realistic liver tissue. More realistic phantoms should be used in treatment plan.&amp;nbsp;&lt;/span&gt;&lt;/font&gt;&lt;font color=&quot;#000000&quot;&gt;&lt;span style=&quot;margin: 0px; line-height: 115%; font-family: &quot;&gt;&lt;span style=&quot;margin: 0px;&quot;&gt; &lt;/span&gt;&lt;/span&gt;&lt;/font&gt;&lt;span style='margin: 0px; line-height: 115%; font-family: &quot;Arial&quot;,sans-serif; font-size: 9pt;'&gt;&lt;/span&gt;&lt;/p&gt;</abstract>
	<keyword_fa>پروتون‌تراپی, شبیه‌سازی, سرطان کبد, SOBP, توزیع دز</keyword_fa>
	<keyword>Proton therapy, Simulation, Liver cancer, Spread-out Bragg Peaks, Dose distribution</keyword>
	<start_page>274</start_page>
	<end_page>287</end_page>
	<web_url>http://jams.arakmu.ac.ir/browse.php?a_code=A-10-6019-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Zahra</first_name>
	<middle_name></middle_name>
	<last_name>Ahmadi Ganjeh</last_name>
	<suffix></suffix>
	<first_name_fa>زهرا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>احمدی گنجه</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>z_ahmadi@stu.yazd.ac.ir</email>
	<code>4600319475328460072723</code>
	<orcid>4600319475328460072723</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Physics, School of Science, Yazd university, Yazd, Iran.</affiliation>
	<affiliation_fa>گروه هسته ای، دانشکده فیزیک، پردیس علوم پایه، دانشگاه یزد، یزد، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad</first_name>
	<middle_name></middle_name>
	<last_name>Eslami-Kalantari</last_name>
	<suffix></suffix>
	<first_name_fa>محمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>اسلامی کلانتری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>meslami@yazd.ac.ir</email>
	<code>4600319475328460072724</code>
	<orcid>4600319475328460072724</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Physics, School of Science, Yazd university, Yazd, Iran.</affiliation>
	<affiliation_fa>گروه هسته ای، دانشکده فیزیک، پردیس علوم پایه، دانشگاه یزد، یزد، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Ali Asghar</first_name>
	<middle_name></middle_name>
	<last_name>Mowlavi</last_name>
	<suffix></suffix>
	<first_name_fa>علی اصغر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مولوی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>aa_mowlavi@yahoo.com</email>
	<code>4600319475328460072725</code>
	<orcid>4600319475328460072725</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Physics, Faculty of Basic Sciences, Campus of Basic Sciences, Hakim Sabzevari University, Sabzevar, Iran.</affiliation>
	<affiliation_fa>گروه فیزیک، دانشکده علوم پایه، پردیس علوم پایه، دانشگاه حکیم سبزواری، سبزوار، ایران.</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
