Abstract:   (4326 Views)
Introduction: Regarding the extensive use of IUD, as contraception. The present study was conduced to evaluate the complications resulting from muliload 375 and T Cu 380A IUD inserted in women referred to the health and treatment settings of Kermanshah medical sciences university in the year 2002.
Materials and Methods: The study was descriptive-analytic, on 122 women using M.L 375 IUD and 245 others using T 380A IUD were fully assessed. The tools used to collect data were questionnaires evaluating the following variables: Pregnancy, bleeding, ectopic pregnancy, uterine perforation, and expulsion, pelvic inflammation disease (PID). To analyze the data, descriptive statistic and X², student-T and Fisher tests were used.
Results: Severe bleeding during menstrual cycle was the most common complication in the two study groups, especially in the multiload 375 IUD group (75% vs. 41.6%; P<0.001). The multiload 375 IUD had a significantly higher dysmenorrhea rate compared to the T cu 380A (%70.8 vs. %40.8; P<0.001). The rate of intera-uterine pregnancy was low for the two device %1.7 vs. %2, and occurrence of ectopic pregnancy in multiload 375 IUD was 0.8% and in T Cu 380A group was not reported. There was no uterine perforation observed for either device.
Conclusion: According to the results gained, the common complications in each group were not dangerous and their severe and threatening complications were uncommon. The most frequent complications were severe bleeding during menstrual period, dysmenorrhea and spotting which were not life threating and could be controlled by supporting and training their users, although these complications were seen more among those using M.L 375 IUD. These two device were effective enough to prevent pregnancy. It seems that using T Cu 380A IUD is more suitable for those who want to have a long-term contraception.
Full-Text [PDF 339 kb]   (274 Downloads)    
Type of Study: Original Atricle | Subject: Oncology
Received: 2021/01/23 | Accepted: 2002/10/2

Add your comments about this article : Your username or Email:
CAPTCHA

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Journal of Arak University of Medical Sciences

Designed & Developed by : Yektaweb