Cheraghi S, Dadfar F, karami A, bamdad K. Cross-sectional Study of Changes in Some Blood Parameters and Sex Hormones in the MRI Department Personnel of Amir Al-Momenin Hospital, Ahvaz. J Arak Uni Med Sci 2026; 29 (2) :91-98
URL: http://jams.arakmu.ac.ir/article-1-8147-en.html
1- Department of Biology, Payame Noor University, Tehran, Iran
2- Department of Biology, Payame Noor University, Tehran, Iran , fdadfar@pnu.ac.ir
Abstract:   (428 Views)
Introduction: The increasing use of electromagnetic waves in industry and medicine, especially in diagnostic devices such as MRI, necessitates a comprehensive study of the effects of electromagnetic fields on the activity of various organs.
Methods: The present study investigated changes in some blood parameters and sex hormones in the MRI department staff of Amir al-Momenin Hospital in Ahvaz. For this purpose, 60 hospital personnel were selected and randomly assigned to two groups: an experimental group (MRI department staff) and a control group (other department staff). An independent samples t-test was used to analyze the data.
Results: Data analysis showed that the levels of luteinizing hormone, follicle-stimulating hormone, and testosterone did not show significant differences in the two groups. In the study of blood parameters, a significant difference was observed in the white blood cell and platelet counts in the experimental group compared to the control group, but no significant differences were observed in other blood parameters between the two groups.
Conclusions: Exposure to electromagnetic fields does not necessarily lead to negative effects, and its potential risks may be activating or inhibitory, depending on physiological characteristics, radiation dose, and duration of exposure.
Full-Text [PDF 1500 kb]   (128 Downloads)    
Type of Study: Original Atricle | Subject: Basic Sciences
Received: 2025/10/12 | Accepted: 2026/02/7

References
1. Chaparian A, Tavakoli I, Karimi V. Organ doses, effective dose, and radiation risk assessment in radiography of pediatric paranasal sinuses. Asian Biomedicine. 2013;7(5):695-8. doi:10.5372/1905-7415.0705.228.
2. Martel J, Chang SH, Chevalier G, Ojcius DM, Young JD. Influence of electromagnetic fields on the circadian rhythm: Implications for human health and disease. Biomed J. 2023;46(1):48-59. pmid: 36681118 doi: 10.1016/j.bj.2023.01.003.
3. Gautam R, Priyadarshini E, Nirala J, Rajamani P. Impact of nonionizing electromagnetic radiation on male infertility: an assessment of the mechanism and consequences. Int J Radiat Biol. 2022;98(6):1063-73. pmid: 33264041 doi: 10.1080/09553002.2020.1859154.
4. Zare A, Mortazavi SMJ. The efficacy of periodic complete blood count tests in evaluation of the health status of radiation workers in Iran: A systematic review. Iran J Public Health. 2020;49(4):628-36. DOI:10.18502/ijph.v49i4.3168 .
5. Rinck PA. Magnetic Resonance in Medicine: A Peer -Reviewed Critical Introduction. 14th ed. TwinTree Publication; 2025. p.7 8-86.
6. Vaziri S, Mirzaei M, Saba F, Salehi Zahabi K, Salehi Zahabi S, Arab-Zozani M. Hematological parameters and X-ray exposure among medical radiation workers: a systematic review and meta-analysis. Expert Rev Hematol. 2022;15(7):645-56. pmid: 35786240 doi: 10.1080/17474086.2022.2096001.
7. Sahoo JK, Joshi AG, Patil SN. A study on how electromagnetic radiation affects the blood system. Journal of Coastal Life Medicine. 2023;11:2785-94.
8. Sabagh M, Chaparian A. Evaluation of Blood Parameters of the Medical Radiation Workers. Iran J Med Phys. 2019;16(6):439-43. doi: 10.22038/ijmp.2019.37427.1477
9. Asghari A, Khaki AA, Rajabzadeh A, Khaki A. A review on Electromagnetic fields (EMFs) and the reproductive system. Electron Physician. 2016;8(7):2655-62. pmid: 27648194 doi: 10.19082/2655.
10. Mollerlokken OJ, Moen BE, Baste V, Magerøy N, Oftedal G, Neto E, et al. No effects of MRI scan on male reproduction hormones. Reprod Toxicol. 2012;34(1):133-9. pmid: 22576112 doi: 10.1016/j.reprotox.2012.04.003.
11. Rostamzadeh A, Anjamrooz SH, Rezaie MJ, Fathi F, Mohammadi M. Biological effects of magnetic resonance imaging on testis histology and seminiferous tubules morphometry. Oman Med J. 2019;34(6):544-52. pmid: 31745419 doi: 10.5001/omj.2019.98.
12. Nassef MH, Kinsara AA. Occupational Radiation Dose for Medical Workers at a University Hospital. Journal of Taibah University for Science. 2017;11(6):1259-66. doi:10.1016/j.jtusci.2017.01.003
13. Ozturk D, Sahin Y, Meletlioglu E. Changes in some hematological parameters in radiology unit workers during the COVID-19 pandemic: Retrospective study. Int J Radiat Res. 2023;21(3):593-6. Doi: 10.52547/ijrr.21.3.32
14. Chain NO. Rodak's Hematology: Clinical Principles and Applications. Platelets.6th ed. 2020. P. 11-5.
15. Gholami M, Mohammadzadeh S, Azarfar A, Gholamipour M. Effects of low frequency of electromagnetic fields in blood parameter of broilers, albumin quality and hatchability [in Persian]. Experimental Animal Biology. 2018;7(1):89-96.
16. Bahrami Asl F, Islami-Seginsara M, Ebrahimi Kalan M, Hemmatjo R, Hesam M, Shafiei-Irannejad V. Exposure to ionizing radiations and changes in blood cells and interleukin-6 in radiation workers. Environ Sci Pollut Res Int. 2023;30(13):35757-68. pmid: 36538225 doi: 10.1007/s11356-022-24652-8.
17. Makvandi S, Yazdizadeh, H, Yazdizadeh, M, Zaker Hoseini V, Madihi R. Effects of Electromagnetic Radiation of Cellular Phone on Parameters of Human Semen Analysis: An In-Vitro Study [in Persian]. Iranian J Obstet, Gynecol Infertil. 2013;16(64):19-25. doi: 10.22038/ijogi.2013.1862
18. Nakamura H, Matsuzaki I, Hatta K, Nobukuni Y, Kambayashi Y, Ogino K. Nonthermal effects of mobile-phone frequency microwaves on uteroplacental functions in pregnant rats. Reprod Toxicol. 2003;17(3):321-6. pmid: 12759101 doi: 10.1016/s0890-6238(03)00010-8.
19. Ai J, Sarkar S, Oghabian MA. Evaluation of electromagnetic radiations (1.5 Tesla) Effect on liver functional tests and histometery of liver in adult male rats [in Persian]. Iranian Journal of Biomedical Engineering. 2010;4(2):161-6. doi: 10.22041/ijbme.2010.13336
20. Hjollund NH, Skotte JH, Kolstad HA, Bonde JP. Extremely low frequency magnetic fields and fertility: a follow up study of couples planning first pregnancies. The Danish First Pregnancy Planner Study Team. Occup Environ Med. 1999;56(4):253-5. pmid: 10450242 doi: 21.1136/oem.56.4.253.
21. Mcgivern RF, Sokol RZ, Adey WR. Prenatal exposure to a low-frequency electromagnetic field demasculinizes adult scent marking behavior and increases accessory sex organ weights in rats. Teratology. 1990;41(1):1-8. pmid: 2106174 doi: 10.1002/tera.1420410102.
22. Margonato V, Nicolini P, Conti R, Zecca L, Veicsteinas A, Cerretelli P. Biologic effects of prolonged exposure to ELF electromagnetic fields in rats: II. 50 Hz magnetic fields. Bioelectromagnetics. 1995;16(6):343-55. pmid: 8789065 doi: 10.1002/bem.2250160602.
23. Monsefi M, Baha-al-dini A, Pirooz M, Haghighi S. Effect of electromagnetic field on ovary and sex hormones of female rat [in Persian]. J Birjand Univ Med Sci. 2004;11(4):9-15.
24. Wang SM, Wang DW, Peng RY, Gao YB, Yang Y, Hu WH, et al. Effect of electromagnetic pulse irradiation on structure and function of Leydig cells in mice [in Chinese]. Zhonghua Nan Ke Xue. 2003;9(5):327-30. Chinese. pmid: 14513635.
25. Dasdag S, Zulkuf Akdag M, Aksen F, Yilmaz F, Bashan M, Mutlu Dasdag M, et al. Whole body exposure of rats to microwaves emitted from a cell phone does not affect the testes. Bioelectromagnetics. 2003;24(3):182-8. pmid: 12669301 doi: 10.1002/bem.10083.
26. Ghanbari M, Mortazavi SB, Khavanin A, Khazaei M. The effects of cell phone waves (900 mhz-gsm band) on sperm parameters and total antioxidant capacity in rats. Int J Fertil Steril. 2013;7(1):21-8. pmid: 24520459;
27. Ozguner M, Koyu A, Cesur G, Ural M, Ozguner F, Gokcimen A, Delibas N. Biological and morphological effects on the reproductive organ of rats after exposure to electromagnetic field. Saudi Med J. 2005;26(3):405-10. pmid: 15806208.

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2026 CC BY-NC 4.0 | Journal of Arak University of Medical Sciences

Designed & Developed by : Yektaweb